Home > News > Content
Maintenance Knowledge Of Filling Machine
Nov 15, 2018

One. Filling machine can't start

1. Connect the power supply, turn on the power switch, check the fuse.

2. The acquittal is hurriedly stopped and twisted.

3. Connect the air pressure and link it to about 6 kg.

4. Check that the switching power supply has dc24v power output.

5. Check whether the touch screen and PLC communication line is loose.

Two: Filling machine not material

1. Check the air pressure, check the touch screen maintenance method screen.

2. Whether the nozzle is closed and the circuit is checked.

3. Feeding.

4. Check the air pressure, raid the injection cylinder and cylinder whether and die, check the touch Screen Repair method screen whether the nozzle closed, raid the circuit.